advertisement

Topcon

Abstract #26957 Published in IGR 12-4

Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes.

Mwanza JC; Chang RT; Budenz DL; Durbin MK; Gendy MG; Shi W; Feuer WJ
Investigative Ophthalmology and Visual Science 2010; 51: 5724-5730


PURPOSE: To assess the reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness and optic nerve head (ONH) parameters measured with Cirrus HD-OCT in glaucomatous eyes. METHODS: Fifty-five glaucomatous eyes were included in the study. The optic disc cube 200 × 200 protocol was used to obtain three scans during the same visit to evaluate the intravisit reproducibility. One scan on 4 additional days within a 2-month period of the first session was obtained to assess intervisit reproducibility. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and test-retest SD (TRT SD) were calculated for each RNFL and ONH parameter. The formula 1.645 × ?2 × intervisit TRT SD provides an upper tolerance limit to variability beyond which nonphysiologic change should be considered. RESULTS: All ICCs were excellent, ranging from 83.9% to 99.2% for intravisit measurements and from 80.8% to 99.1% for intervisit measurements. Cup/disc area ratio had the lowest CV (1.1%) in either type of measurement, followed by average RNFL thickness (1.9% and 2.7%). Nasal clock hours and quadrants showed the poorest reproducibility as did the clock hour directly temporally. The intervisit tolerance limit for average RNFL thickness was 3.89 ?m. CONCLUSIONS: Intravisit and intervisit measurements of peripapillary RNFL thickness and ONH parameters with Cirrus HD-OCT showed excellent reproducibility, indicating that this instrument may be useful in monitoring glaucoma progression. When comparing two measurements from the same eye on two different visits, a reproducible decrease in average RNFL thickness of approximately 4 ?m or more may be considered a statistically significant change from baseline.

Bascom Palmer Eye Institute, Miller School of Medicine, University of Miami, Miami, Florida 33136, USA.


Classification:

6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
2.13 Retina and retinal nerve fibre layer (Part of: 2 Anatomical structures in glaucoma)
2.14 Optic disc (Part of: 2 Anatomical structures in glaucoma)



Issue 12-4

Change Issue


advertisement

WGA Rescources