advertisement

Topcon

Abstract #53949 Published in IGR 15-2

The biometric study in different stages of primary angle-closure glaucoma

Chen YY; Sheu SJ; Chou P
Eye 2013; 27: 1070-1076


PURPOSE: This study compared the general and ocular biometric characteristics of normal, primary angle closure (PAC), and primary angle-closure glaucoma (PACG) patients to better understand the possible relationship between differences in ocular parameters that might predict risk for PACG in PAC patients. METHODS: One hundred normal, 90 PAC, and 90 PACG eyes were retrospectively reviewed. General characteristics such as age, gender, body height, body weight, blood pressure, pulse, systemic diseases, and education level were recorded. Ocular findings included visual acuity, intraocular pressure, refraction, cup to disc ratio, and ocular biometry. Ocular biometry was obtained by A-scan ultrasonography (Digital A/B scan 5500; Sonomed Inc., Lake Success, NY, USA). The parameters recorded were anterior chamber depth (ACD), lens thickness (LT), axial length (AXL), lens/axial length factor (LAF), and relative lens position (RLP). RESULTS: Although the controls, PAC group, and PACG group were found to be significantly different in age (62.7±9.8; 65.3±7.5; and 66.0±7.4, respectively), there were no gender differences. With regard to ocular parameters, the ACD tended to decrease and the LT and LAF tended to increase from normal to PAC to PACG. The eyes of the PACG group had significantly shallower ACD (P<0.001) and thicker lens (P<0.001) than those of the PAC group. While PAC had similar lens position to the control group, PACG had more anteriorly positioned lens than the PAC group (P<0.001). Logistic regression analysis found a significant association between a decrease in ACD and increased risk of PACG (odds ratio (OR)=3.59 for 0.2 mm decrease in ACD) as well as a significant association between an increase in LT and increased risk of PACG (OR=1.30). CONCLUSIONS: In addition to LT, a shallower ACD owing to a change in RLP may have a role in the progression from PAC to PACG. Owing to the differences of certain biometric characteristics between PAC and PACG, A-scan ultrasonography might potentially be used for the early detection of PACG in PAC eyes.Eye advance online publication, 21 June 2013; doi:10.1038/eye.2013.127.

1] Department of Public Health and Institute of Public Health, National Yang-Ming University, Taipei, Taiwan [2] Department of Ophthalmology, Madou Sin-Lau Hospital, Tainan County, Taiwan.

Full article

Classification:

9.3.5 Primary angle closure (Part of: 9 Clinical forms of glaucomas > 9.3 Primary angle closure glaucomas)
9.3.1 Acute primary angle closure glaucoma (pupillary block) (Part of: 9 Clinical forms of glaucomas > 9.3 Primary angle closure glaucomas)
9.3.2 Chronic primary angle closure glaucoma (pupillary block) (Part of: 9 Clinical forms of glaucomas > 9.3 Primary angle closure glaucomas)



Issue 15-2

Change Issue


advertisement

Oculus