advertisement

Topcon

Abstract #66543 Published in IGR 17-3

Normative Spectral Domain Optical Coherence Tomography Data in Healthy Turkish Children

Gürağaç FB; Totan Y; Güler E; Tenlik A; Ertuğrul İG
Seminars in Ophthalmology 2016; 0: 1-7


PURPOSE: To determine the normative database of macular and retinal nerve fiber layer (RNFL) thickness parameters in healthy Turkish children by OCT. METHODS: 318 eyes of 318 children (138 boys, 183 girls) aged between 3 and 17 years were evaluated. The children were scanned by Cirrus HD-OCT (Carl Zeiss Meditec) to measure the macula, RNFL, and optic nerve head parameters. RESULTS: Axial length (AL) (p < 0.001, R(2 )= 0.08), spherical equivalent (SE) (p < 0.001, R(2 )= 0.12), and rim area (p < 0.001, R(2 )= 0.15) were the strongest predictors of RNFL thickness. All of the macular measurements were significantly related to age (p < 0.001, R(2 )> 5%). Average macular thickness (p < 0.01) and outer macula (p = 0.002) showed significant relationship with the AL and SE. CONCLUSION: This study ensures an age-adjusted pediatric normative database using OCT to diagnose and monitor macular diseases, optic nerve diseases, and glaucoma in children.

a Gölbaşı Hasvak State Hospital, Eye Clinic , Ankara , Turkey .

Full article

Classification:

6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
9.1.2 Juvenile glaucoma (Part of: 9 Clinical forms of glaucomas > 9.1 Developmental glaucomas)



Issue 17-3