Fourier analysis of optical coherence tomography and scanning laser polarimetry retinal nerve fiber layer measurements in the diagnosis of glaucoma

Essock EA; Sinai MJ; Bowd C; Zangwill LM; Weinreb RN
Archives of Ophthalmology 2003; 121: 1238-1245


OBJECTIVE: To evaluate a new Fourier-based analysis method for diagnosing glaucoma using retinal nerve fiber layer (RNFL) thickness estimates obtained from the optical coherence tomograph (OCT) (OCT 2000) and the scanning laser polarimeter (GDx). METHODS: The authors obtained RNFL thickness estimates from one eye each of 38 healthy individuals and 42 patients with early glaucomatous visual field loss using the OCT and GDx devices. The shape of the RNFL double-hump pattern was assessed using Fourier analysis, and values were entered into a linear discriminant analysis. Receiver operating characteristic (ROC) curves were used to compare the performance of the Fourier-based metrics against other commonly used RNFL analytical procedures. Reliability was assessed on independent samples by the split-half method. Correlations were calculated to determine the extent to which the Fourier discriminant measurements and other RNFL measurements covaried between the two devices and the relationship between these RNFL and visual field measurements. RESULTS: Sensitivity and specificity for the linear discriminant function (LDF) based on the Fourier analysis of the OCT data were 76 and 90%, respectively, and the area under the ROC curve was 0.925 (SEM, 0.028). For the GDx data, the Fourier-based LDF yielded sensitivity and specificity of 82 and 90%, respectively, with an ROC curve area of 0.928 (SEM, 0.029). These values were better than those determined using the GDx number, a previous discriminant function using GDx variables and OCT thickness values. The Fourier-based LDFs and numerous other measurements were significantly correlated between the two devices. For each device, the visual field measures correlated most highly with the Fourier-based LDF measure. CONCLUSIONS: For both devices, the LDF based on the output from a Fourier analysis of RNFL data resulted in better diagnostic capability compared with other common RNFL analytical procedures. That this technique improves RNFL analysis is also supported by the better correlations between visual field and Fourier-based LDF measurements.

Dr. E.A. Essock, Department of Psychological and Brain Sciences, University of Louisville, Louisville, KY 40292, USA. essock@louisville.edu


Classification:

6.9.1 Laser scanning (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis)
6.9.2 Optical coherence tomography (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis)



Issue 5-3

Change Issue


advertisement

Topcon