advertisement
See also comment(s) by Rupert Bourne •
PURPOSE: To model whether more frequent (weekly, monthly) visual field assessments using portable, "home" perimetry, might more quickly detect glaucoma progression in a clinical trial context. DESIGN: Cross-sectional with additional simulations PARTICIPANTS: 40 patients (78 eyes; n=21 healthy, n=16 glaucoma suspects, n=41 manifest glaucoma) METHODS: Participants performed an interleaved sequence of two portable (Eyecatcher v3.0; EC3) and two reference (HFA SITA-Fast) visual field tests (4 tests total per eye). Linear mixed modelling was then applied to one randomly selected eye per patient to mathematically predict the expected proportion of progressors detected by EC3/HFA over a 3-year period, given different testing regimens (from weekly to every 4 months), levels of variability, and underlying rates of true progression. MAIN OUTCOME MEASURES: Test-retest variability. Proportion of progressors detected. RESULTS: The portable perimeter was significantly less reliable: the Bland-Altman 95% coefficient of repeatability for Mean Deviation (CoR) was 6.37 dB for EC3, and 4.25 dB for the HFA. Statistical simulations, however, predicted that this lower reliability would be offset by more frequent testing. Thus, modelling indicated one EC3 test per month would detect a higher proportion of slow (-0.5 dB/year), moderate (-1dB/year) and fast (-2dB/year) progressors compared to one HFA test every four months. Implications for trial sample sizes were also modelled, with the number of participants required to evidence a 20% reduction in baseline progression over two years (following a hypothetical intervention) predicted to decrease by 24.3%/36.3% with the addition of monthly/fortnightly home testing. There was no significant difference in mean test duration between the EC3 and HFA (226 vs 225 seconds, P = 0.78), and participants rated the EC3 as somewhat easier to use (system usability scale; P = 0.004). CONCLUSIONS: Home VF assessments, despite poorer reliability than current reference standard ("in-clinic") devices, would allow faster/greater detection of glaucoma progression via an increased frequency of testing, and/or could reduce the sample size requirements of future clinical trials. Implications on duration, access and overall cost are discussed.
Department of Optometry and Visual Sciences, School of Health & Medical Sciences, City St George's, University of London, London, England, EC1V 0HB; Save Sight Institute, University of Sydney, Camperdown, NSW, Australia; Prince of Wales hospital eye clinic, High Street, Level 4, The Prince of Wales Hospital, High Street Building, Randwick, NSW, 2031, Australia. Electronic address: Jeremy.c.tan@unsw.edu.au.
Full article