advertisement

Topcon

Abstract #22948 Published in IGR 11-1

Correlation between structural and functional analysis in glaucoma suspects

Chiselita D; Danielescu C; Apostol A
Oftalmologia 2008; 52: 111-118


PURPOSE: To establish correlations between structural and functional parameters in glaucoma suspects. METHOD: In 43 patients (83 eyes) of glaucoma patients we have performed standard automated perimetry, scanning laser polarimetry (GDx-VCC) of the retinal nerve fiber layer (RNFL) and optical coherence tomography (Stratus OCT) of the RNFL and optic disc. RESULTS: Diagnostic concordance (achieved if one eye is deemed normal--respectively abnormal--by both tests) was 60.24% between perimetry and OCT respectively 61.44% between perimetry and GDx. The Areas under the Receiver Operating Characteristic curve were between 0.524-0.574 for OCT parameters and 0.518-0.548 for GDx parameters (considering the visual field examination as "gold standard"). The correlation between RNFL measurements in OCT and GDx took values between r = 0.481 and r = 0.352. CONCLUSIONS: Structural and functional damage are not consistent with each other in early glaucoma, resulting in the fact that both tests should be used in the diagnostic strategy LA: Romanian

Dr. D. Chiselita, Clinica I Oftalmologie, Iasi, Romania


Classification:

6.9.2.2 Posterior (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.2 Optical coherence tomography)
6.9.1.2 Confocal Scanning Laser Polarimetry (Part of: 6 Clinical examination methods > 6.9 Computerized image analysis > 6.9.1 Laser scanning)
6.6.2 Automated (Part of: 6 Clinical examination methods > 6.6 Visual field examination and other visual function tests)



Issue 11-1

Change Issue


advertisement

Topcon