PURPOSE: To determine whether monoscopic vs stereoscopic viewing impacts evaluation of optic disc photographs for glaucoma diagnosis in an expert population. DESIGN: Prospective observational study. METHODS: Twenty pairs of high-quality monoscopic and stereoscopic photographs of similar size and magnification (ie, 40 images), were selected to demonstrate a range of optic disc features from a total of 197 eyes of 197 patients with glaucoma and normal subjects recruited from a tertiary clinic. These were presented in randomized order via an interactive platform (http://stereo.gone-project.com/). Participants assessed 9 topographic features and estimated glaucoma likelihood for each photograph. Main outcome measures were intra- and inter-observer agreement. RESULTS: There was good intra-observer agreement between monoscopic and stereoscopic assessments of glaucoma likelihood (κw = 0.56). There was also good to substantial agreement for peripapillary atrophy (κw = 0.65), cup shape (κw = 0.65), retinal nerve fiber layer loss (κw = 0.69), vertical cup-to-disc ratio (κw = 0.58), and disc shape (κw = 0.57). However, intra-observer agreement was only fair to moderate for disc tilt, cup depth, and disc size (κw = 0.46-0.49). Inter-observer agreement for glaucoma likelihood in monoscopic photographs (κw = 0.61, 95% confidence interval [CI] = 0.55-0.67) was substantial and not lower than in stereoscopic photographs (κw = 0.59, CI = 0.54-0.65). Monoscopic photographs did not lead to lower levels of inter-observer agreement compared to stereoscopic photographs in the assessment of any optic disc characteristics, for example disc size (mono κw = 0.65, stereo κw = 0.52) and cup-to-disc ratio (mono κw = 0.72, stereo κw = 0.62). CONCLUSIONS: For expert observers in the evaluation of optic disc photographs for glaucoma likelihood, monoscopic optic disc photographs did not appear to represent a significant disadvantage compared to stereoscopic photographs.

Full article

Classification:

6.3.2 Posterior segment (Part of: 6 Clinical examination methods > 6.3 Biomicroscopy (slitlamp))
2.14 Optic disc (Part of: 2 Anatomical structures in glaucoma)



Issue 16-1

Change Issue


advertisement

Topcon