advertisement

Topcon

Abstract #107513 Published in IGR 23-4

Corticosteroid implants for chronic non-infectious uveitis

Reddy A; Liu SH; Brady CJ; Sieving PC; Palestine AG
Cochrane Database of Systematic Reviews 2023; 1: CD010469


BACKGROUND: Uveitis is a term used to describe a group of intraocular inflammatory diseases. Uveitis is the fifth most common cause of vision loss in high-income countries, with the highest incidence of disease in the working-age population. Corticosteroids are the mainstay of treatment for all subtypes of non-infectious uveitis. They can be administered orally, topically with drops, by periocular (around the eye) or intravitreal (inside the eye) injection, or by surgical implantation. OBJECTIVES: To determine the efficacy and safety of steroid implants in people with chronic non-infectious posterior uveitis, intermediate uveitis, and panuveitis. SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register), MEDLINE Ovid, Embase, PubMed, LILACS, and three trials registries to November 2021. SELECTION CRITERIA: We included randomized controlled trials comparing either fluocinolone acetonide (FA) or dexamethasone (DEX) intravitreal implants with standard-of-care therapy or sham procedures, with at least six months of follow-up after treatment. We included studies that enrolled participants of all ages, who had chronic non-infectious posterior uveitis, intermediate uveitis, or panuveitis with vision that was better than hand-motion. DATA COLLECTION AND ANALYSIS: We applied standard Cochrane methodology. MAIN RESULTS: We included data from four trials (683 participants, 907 eyes) that compared corticosteroid implants with either sham or standard-of-care therapy. Study characteristics and risk of bias Of the two trials that compared corticosteroid implants with sham procedure, one examined a 0.18 mg FA implant, and the other, a 0.7 mg DEX implant. The other two trials compared a 0.59 mg FA implant with standard-of-care therapy, which included systemic corticosteroids and immunosuppressive medications, if needed. We assessed the four trials to be at either low risk, or with some concerns of risk of bias across all domains. Findings Using sham procedure as control, combined results at the six-month primary time point suggested that corticosteroid implants may decrease the risk of uveitis recurrence by 60% (relative risk [RR] 0.40, 95% confidence interval [CI] 0.30 to 0.54; 2 trials, 282 participants; low-certainty evidence); and lead to a greater improvement in best-corrected visual acuity (BCVA; mean difference [MD] 0.22 logMAR, 95% CI 0.13 to 0.31; 1 trial, 153 participants; low-certainty evidence). Evidence based on a single-study report (146 participants) suggested that steroid implants may have no effects on visual functioning quality of life, measured on the National Eye Institute 25-Item Visual Function Questionnaire (MD 2.85, 95%CI -3.64 to 9.34; 1 trial, 146 participants; moderate-certainty evidence). Using standard-of care therapy as control, combined estimates at the 24-month primary time point suggested that corticosteroid implants were likely to decrease the risk of recurrence of uveitis by 54% (RR 0.46, 95% CI 0.35 to 0.60; 2 trials, 619 eyes). Combined estimates at 24 months also suggested that steroid implants may have little to no effects on BCVA (MD 0.05 logMAR, 95% CI -0.02 to 0.12; 2 trials, 619 eyes; low-certainty evidence). Evidence based on a single-study report (232 participants) suggested that steroid implants may have minimal clinical effects on visual functioning (MD 4.64, 95% CI 0.13 to 9.15; 1 trial, 232 participants; moderate-certainty evidence); physical functioning (SF-36 physical subscale MD 2.95, 95% CI 0.55 to 5.35; 1 trial, 232 participants; moderate-certainty evidence); or mental health (SF-36 mental subscale MD 3.65, 95% CI 0.52 to 6.78; 1 trial, 232 participants; moderate-certainty evidence); but not on EuroQoL (MD 6.17, 95% CI 1.87 to 10.47; 1 trial, 232 participants; moderate-certainty evidence); or EuroQoL-5D scale (MD 0.02, 95% CI -0.04 to 0.08; 1 trial, 232 participants; moderate-certainty evidence). Adverse effects Compared with sham procedures, corticosteroid implants may slightly increase the risk of cataract formation (RR 2.69, 95% CI 1.17 to 6.18; 1 trial, 90 eyes; low-certainty evidence), but not the risk of cataract progression (RR 2.00, 95% CI 0.65 to 6.12; 1 trial, 117 eyes; low-certainty evidence); or the need for surgery (RR 2.98, 95% CI 0.82 to 10.81; 1 trial, 180 eyes; low-certainty evidence), during up to 12 months of follow-up. These implants may increase the risk of elevated intraocular pressure ([IOP] RR 2.81, 95% CI 1.42 to 5.56; 2 trials, 282 participants; moderate-certainty evidence); and the need for IOP-lowering eyedrops (RR 1.85, 95% CI 1.05 to 3.25; 2 trials, 282 participants; moderate-certainty evidence); but not the need for IOP-lowering surgery (RR 0.72, 95% CI 0.13 to 4.17; 2 trials, 282 participants; moderate-certainty evidence). Evidence comparing the 0.59 mg FA implant with standard-of-care suggested that the implant may increase the risk of cataract progression (RR 2.71, 95% CI 2.06 to 3.56; 2 trials, 210 eyes; low-certainty evidence); and the need for surgery (RR 2.98, 95% CI 2.33 to 3.79; 2 trials, 371 eyes; low-certainty evidence); along with the risk of elevated IOP (RR 3.64, 95% CI 2.71 to 4.87; 2 trials, 605 eyes; moderate-certainty evidence); and the need for medical (RR 3.04, 95% CI 2.36 to 3.91; 2 trials, 544 eyes; moderate-certainty evidence); or surgical interventions (RR 5.43, 95% CI 3.12 to 9.45; 2 trials, 599 eyes; moderate-certainty evidence). In either comparison, these implants did not increase the risk for endophthalmitis, retinal tear, or retinal detachment (moderate-certainty evidence). AUTHORS' CONCLUSIONS: Our confidence is limited that local corticosteroid implants are superior to sham therapy or standard-of-care therapy in reducing the risk of uveitis recurrence. We demonstrated different effectiveness on BCVA relative to comparators in people with non-infectious uveitis. Nevertheless, the evidence suggests that these implants may increase the risk of cataract progression and IOP elevation, which will require interventions over time. To better understand the efficacy and safety profiles of corticosteroid implants, we need future trials that examine implants of different doses, used for different durations. The trials should measure core standard outcomes that are universally defined, and measured at comparable follow-up time points.

Department of Ophthalmology, University of Colorado Anschutz Medical Campus, School of Medicine, Aurora, Colorado, USA.

Full article

Classification:

15 Miscellaneous



Issue 23-4

Change Issue


advertisement

Oculus