advertisement

Topcon

Abstract #108604 Published in IGR 23-4

Phase I NT-501 Ciliary Neurotrophic Factor Implant Trial for Primary Open-Angle Glaucoma: Safety, Neuroprotection, and Neuroenhancement

Goldberg JL; Beykin G; Satterfield KR; Nuñez M; Lam BL; Albini TA
Ophthalmology science 2023; 3: 100298

See also comment(s) by Keith Martin


PURPOSE: To assess the safety and efficacy of a ciliary neurotrophic factor (CNTF) intraocular implant on neuroprotection and neuroenhancement in glaucoma. DESIGN: Open-label, prospective, phase I clinical trial. PARTICIPANTS: A total of 11 participants were diagnosed with primary open-angle glaucoma (POAG). One eye of each patient was assigned as the study (implant) eye. METHODS: The study eye was implanted with a high-dose CNTF-secreting NT-501 implant, whereas the other eye served as a control. All patients were followed up for 18 months. Analysis was limited to descriptive statistics. MAIN OUTCOME MEASURES: Primary outcome was safety through 18 months after implantation assessed by serial eye examinations, structural and functional testing, and adverse events (AEs) recording. Parameters measured included visual acuity (VA), Humphrey visual field (HVF), pattern electroretinogram, scanning laser polarimetry with variable corneal compensation (GDx VCC), and OCT. These parameters were also used for secondary analysis of efficacy outcome. RESULTS: All NT-501 implants were well tolerated with no serious AEs associated with the implant. The majority of AEs were related to the implant placement procedure and were resolved by 12 weeks after surgery. Foreign-body sensation was the most commonly reported AE and was self-limited to the postoperative period. The most common implant-related AE was pupil miosis; no patients underwent explant. Visual acuity and contrast sensitivity decreased more in fellow eyes than in study eyes (VA, -5.82 vs. -0.82 letters; and contrast sensitivity, -1.82 vs. -0.37 letters, for fellow vs. study eyes, respectively). The median HVF visual field index and mean deviation measurements worsened (decreased) in fellow eyes (-13.0%, -3.9 dB) and improved (increased) in study eyes (2.7%, 1.2 dB). Implanted eyes showed an increase in retinal nerve fiber layer thickness measured by OCT and by GDx VCC (OCT, 2.66 μm vs. 10.16 μm; and GDx VCC, 1.58 μm vs. 8.36 μm in fellow vs. study eyes, respectively). CONCLUSIONS: The NT-501 CNTF implant was safe and well tolerated in eyes with POAG. Eyes with the implant demonstrated both structural and functional improvements suggesting biological activity, supporting the premise for a randomized phase II clinical trial of single and dual NT-501 CNTF implants in patients with POAG, which is now underway. FINANCIAL DISCLOSURES: Proprietary or commercial disclosure may be found after the references.

Full article

Classification:

15 Miscellaneous



Issue 24-3

Change Issue


advertisement

Topcon