A New Contact Lens Sensor System for Continuous Intraocular Pressure Monitoring: Evaluation of Safety and Tolerability

Zhang Y; Wei Y; Karunaratne IK; Lee CHC; Deng M; Chen Z; Yang Y; Chong IT; Chong IT; Lam DCC; Lam DCC; Yu M
Eye Contact Lens 2022; 48: 439-444


PURPOSE: To assess the safety and tolerability of a new contact lens sensor (CLS) system for continuous 3- and 24-hr intraocular pressure (IOP) monitoring in human eyes. METHODS: Twenty-five subjects were recruited for 3-hr IOP measurement by CLS. Corneal fluorescein staining (CFS) scores were evaluated before and after measurement. Then, 30 participants (10 normal subjects and 20 glaucoma patients) were recruited for 24-hr IOP monitoring. Ocular surface disease index (OSDI) was assessed before and one day after measurement. Contact lens dry eye questionnaire-8 was assessed immediately after measurement. Visual analog scale of discomfort was measured before, immediately after, and one day after measurement. Best-corrected visual acuity (BCVA), tear break-up time (TBUT), and CFS were assessed before, immediately after, and 1 day after measurement. RESULTS: All participants completed 3- or 24-hr IOP measurement by CLS. Corneal fluorescein staining increased from 0.6±0.7 to 2.4±1.5 after 3-hr IOP measurement ( P <0.001). For participants undergoing 24-hr IOP monitoring, OSDI increased from 9.1±9.7 to 18.0±12.4 ( P =0.001). CLDEQ-8 score was 11.6±5.8. Visual analog scale increased from 11.1±14.2 to 35.2±21.8 after measurement ( P <0.001) and decreased to 26.7±18.4 one day later ( P <0.001 compared with baseline). BCVA decreased from 1.0±0.01 to 0.8±0.1 ( P <0.001) and returned to 0.9±0.1 after one day ( P <0.001 compared with baseline). TBUT decreased from 5.1±3.9 to 2.6±1.5 s ( P =0.001) and returned to 4.8±2.5 s ( P =0.465 compared with baseline). Corneal fluorescein staining increased from 0.7±0.9 to 4.3±0.8 ( P <0.001) and dropped to 0.8±0.7 ( P =0.599 compared with baseline). No significant difference was found for all variations of indicators between normal subjects and glaucoma patients ( P >0.1 for all comparisons). CONCLUSIONS: The CLS shows a great potential for a safe and tolerable 24-hr IOP monitoring in normal subjects and glaucoma patients. Clinical attention to the worsening signs and symptoms after measurement is required.

State Key Laboratory of Ophthalmology (Y.Z., Y.W., M.D., Z.C., Y.Y., M.Y.), Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China; and Department of Mechanical and Aerospace Engineering (I.K.K., C.H.C.L., I.T.C., D.C.C.L.), The Hong Kong University of Science and Technology, Hong Kong, China.

Full article

Classification:

15 Miscellaneous



Issue 23-2

Change Issue


advertisement

Oculus