advertisement

WGA Rescources

Abstract #13805 Published in IGR 8-2

Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients

Brusini P; Salvetat ML; Zeppieri M; Tosoni C; Parisi L
Journal of Glaucoma 2006; 15: 213-217


PURPOSE: To compare the intraocular pressure (IOP) readings taken with the new ICare tonometer and with the Goldmann applanation tonometer (GAT) and to evaluate the influence of central corneal thickness (CCT) on the IOP measurements. PATIENTS AND METHODS: One eye of 178 consecutive patients with primary open-angle glaucoma underwent ultrasonic CCT measurement, followed by IOP evaluation with the GAT and with the ICare tonometer. The deviation of ICare readings from GAT values, corrected according to the Doughty and Zaman formula, was calculated and correlated to CCT by a linear regression model. The agreement between the two devices was assessed by use of the Bland-Altman method. RESULTS: The average CCT was 552 ± 39 μm. The mean IOP and the mean corrected IOP with GAT were 19.4 ± 5.4 mmHg, and 18.5 ± 5.7 mmHg, respectively. The mean ICare IOP reading was 18.4 ± 5.2 mmHg. The deviations of ICare readings from corrected GAT values were highly correlated with CCT values (r = 0.63, P < 0.01). Linear regression analysis showed that a CCT change of 10 μm resulted in an ICare reading deviation of 0.7 mmHg. The Bland-Altman scatter-plot showed a reasonable agreement between the two tonometers. CONCLUSIONS: The ICare tonometer can be useful in a routine clinical setting. The IOP readings are quite in accordance with those obtained by GAT. The measurements seemed to be influenced by CCT variations, and thus pachymetry should always be taken into consideration.

Dr. P. Brusini, Department of Ophthalmology, Santa Maria della Misericordia Hospital, Udine, Italy


Classification:

6.1 Intraocular pressure measurement; factors affecting IOP (Part of: 6 Clinical examination methods)



Issue 8-2

Change Issue


advertisement

Oculus